The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W.

 

 

 

The ANN-80 annunciator is a compact, backlit, 80-character LCD fire annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. The ANN-80 and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format. Connected devices are powered, via two additional wires, by either the host FACP or a remote UL-listed, filtered power supply. ANN-80 is red; for white, order ANN-80-W.

 

The ANN-RLY relay module provides 10 programmable Form- C relays when used with a compatible FACP (Fire Alarm Control
Panel). The ANN-RLY module may be mounted inside the FACP main circuit board chassis or in the battery area of the enclosure using optional mounting bracket P/N: ANN-MBRLY.

 

 

 

 

 

 

The ANN-I/O is an LED driver module that can be used in a wide variety of applications including as an interface with the Fire Alarm Control Panel (FACP) to drive most customized graphic annunciators. It comes in a plastic enclosure that may be mounted inside a custom annunciator or accessory cabinet and can drive up to 40 LEDs'

The ANN-I/O and the FACP communicate over a two-wireserial interface employing the ANN-BUS communication format.  An additional two wires are used for 24-volt DC power. A single four-conductor unshielded cable may be used for both power and data communications. Up to eight ANN-BUS devices may be connected to the ANNBUS of each FACP.

 

The ANN-S/PG Interface module connects either a serial orparallel printer with a compatible Fire Alarm Control Panel(FACP) to print real-time logs of system events, detector status reports, and event histories.

The ANN-S/PG and the FACP communicate over a two-wireserial interface employing the ANN-BUS communication format.  An additional two wires are used for 24-volt DC power. A single four-conductor unshielded cable may be used for both power and data communications.  Up to eight ANN-S/PGs may be connected to the ANN-Bus ofeach FACP.

 

 

 

The ANN-LED annunciator module provides LED annunciation of general system faults and input zones/points when used with a compatible Fire Alarm Control Panel (FACP). The ANNLED module provides alarm (red), trouble (yellow) and supervisory (yellow) indication for up to ten input zones or addressable points. ANN-RLED has red LEDs only for alarm communication of up to 30 addressable points.  The ANN-LED is supplied standard with certain Canadian FACPs as required by ULC.  The ANN-LED and the FACP communicate over a two-wire serial interface employing the ANN-BUS communication format.  An additional two wires are used for 24-volt DC power. A single four-conductor unshielded cable may be used for both power and data communications.  Up to eight ANN-BUS devices may be connected to the ANNBUS of each FACP.

 

The Relay Module provides 10 programmable Form-C relays when used with a compatible FACP (Fire Alarm Control Panel). This document is provided as a quick reference. For more detailed programming information, refer to the appropriate FACP installation manual.